Portuguese English Spanish
Portuguese English Spanish

November 13, 2026

These are the Release Notes for the new version of NDD Orbix, listing all the features included in this update.

To view updates to the integration APIs, access the API Release Notes.


Updated modules

  • Printer Management
    🔁 Update required: DCA and Cloud Connector (Windows), version 1.2.34


Printer Management

🔧 UPDATE | Printers without a serial number are not monitored (NDD - Printer Monitor | 1.2.1 | Windows)
UPDATE | Printers without a serial number are not monitored (NDD - Printer Monitor | 1.2.1 | Windows)

Previously, a printer was not monitored when the scan did not return the serial number and MAC address. Now, it will not be monitored when the scan does not return the serial number.

In this situation, the system records an informational log entry with the address, manufacturer, and model:

Printer {address} - {manufacturer} {model} will not be monitored because it has no serial number.
🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🛠️ IMPROVEMENT | Monitoring printers with SHA-256 and SHA-512 in SNMP V3 (NDD - Printer Monitor | 1.2.1 | Windows)
IMPROVEMENT | Monitoring printers with SHA-256 and SHA-512 in SNMP V3 (NDD - Printer Monitor | 1.2.1 | Windows)
  • Locations: Facilities > Services > Settings > Communication or Facilities > Installers > Generate Installer > Install Network Printer Monitoring

You can now select SHA-256 or SHA-512 as the authentication algorithm in the SNMP V3 settings for the network printer monitoring service. To configure this, go to the Installations > Services menu, open the desired service, and click the Settings > Communication tab. When adding or editing an SNMP configuration, select the algorithm configured on the printer.

The NDD - Printer Monitor service will use the selected algorithm when querying the printer. This allows you to monitor equipment compatible with SHA-256 or SHA-512 and expand compatibility with environments that use these algorithms.

Warning

Support is available for the SNMP V3 authentication algorithm, which is used only by the NDD - Printer Monitor service, starting with version 1.2.1.

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🛠️ IMPROVEMENT | Improved reliability for USB printing on the Lexmark MS521dn and MS520 models (NDD - Printer Monitor USB | 1.1.23 | Windows)
IMPROVEMENT | Improved reliability for USB printing on the Lexmark MS521dn and MS520 models (NDD - Printer Monitor USB | 1.1.23 | Windows)

We have improved the collection of information from Lexmark MS521dn and MS520 printers connected via USB in Windows environments, particularly in situations where the total counter was not being collected correctly.

With this improvement, we have enhanced the reliability of data collection for these models without affecting the monitoring of other equipment.

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor USB | 1.1.23 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🐞 FIX | Network printer monitoring data was not being updated (NDD - Printer Monitor | 1.2.1 | Windows)
FIX | Network printer monitoring data was not being updated (NDD - Printer Monitor | 1.2.1 | Windows)

Network printers stopped sending monitoring data and remained out of sync when they did not correctly return the MAC address (MacAddress).

The problem occurred during the automatic cycle, after a period of monitoring. The updates resumed after a manual search for printers.

To fix this, printers are now identified by their serial numbers, and the automatic cycle resumed sending data without requiring a manual search.

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🐞 FIX | Network printers registered by hostname are not being detected in monitoring (NDD - Printer Monitor | 1.2.1 | Windows)
FIX | Network printers registered by hostname are not being detected in monitoring (NDD - Printer Monitor | 1.2.1 | Windows)

When adding a printer by hostname in the monitored network addresses, the equipment might not be found during the search, preventing it from being monitored.

We have adjusted the search process so that printers are found and monitored correctly, while retaining the hostname specified in the configuration.

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🐞 FIX | Supplies not being picked up on HP LaserJet M507 printers (NDD - Printer Monitor | 1.2.1 | Windows)
FIX | Supplies not being picked up on HP LaserJet M507 printers (NDD - Printer Monitor | 1.2.1 | Windows)

While performing monitoring of HP LaserJet M507 printers, supply information was not being collected correctly.

We have adjusted the collection process to ensure that supply levels for this model are monitored and displayed correctly.

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🐞 FIX | Printers with SNMP v3 are not being found in the search (NDD - Printer Monitor | 1.2.1 | Windows)
FIX | Printers with SNMP v3 are not being found in the search (NDD - Printer Monitor | 1.2.1 | Windows)

Printers configured with SNMP v3 might not be found during a direct search by network address, preventing them from being monitored.

We have adjusted the search process to ensure that these devices are found and monitored correctly.

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🖨️ APPROVAL | Approved network printers (NDD - Printer Monitor | 1.2.1 | Windows)
APPROVAL | Approved network printers (NDD - Printer Monitor | 1.2.1 | Windows)
  • Network printers approved for collecting meters and supplies

    • BROTHER MFC-L9670CDN

    • CANON GX5010¬GX5000

    • CANON iR-ADV 4935

    • CANON IMAGEFORCE-C1333

    • CANON GX2010¬GX2000

    • LEXMARK C4342

    • LEXMARK XC2342

    • LEXMARK CX622ade

    • LEXMARK XC9525

    • LEXMARK XC2132

    • SAMSUNG SL-M4080FX

    • SHARP BP71M65

  • Network printers adjusted

    • CANON iPF670

    • CANON TM-300

    • BROTHER MFC-L6910DN

    • HP COLOR LASERJET FLOW E87660

    • LEXMARK CS921de

    • LEXMARK CX431adw

    • LEXMARK CX921de e CS921de

    • XEROX ALTALINK C8170

    • SAMSUNG M4080FX

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor | 1.2.1 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

🖨️ APPROVAL | Approved USB printers (NDD - Printer Monitor USB | 1.1.23 | Windows)
APPROVAL | Approved USB printers (NDD - Printer Monitor USB | 1.1.23 | Windows)
  • Incompatible USB printers

    • HP LASERJET FLOW MFP M527

🔁

Update required

  • DCA and Cloud Connector | 1.2.34 | Windows

  • NDD - Printer Monitor USB | 1.1.23 | Windows

To update, access Update the DCA and Cloud Connector agent, Gateway Connector, or services version via the portal.

📚 DOCUMENTATION | Documentation improvement based on feedback
DOCUMENTATION | Documentation improvement based on feedback

Based on feedback sent via the “What did you think of this page?” option, we have added additional information to guide the SNMP configuration version 3.

Last updated: